Details
Mechanical properties and environmental adaptability
Plug and remove durability: The number of plug - and - remove times is > 5000 times. It can adapt to frequent plug - and - remove operations.
Humidity adaptability: At 60°C, it can still work normally when the humidity is as high as 95%.
Temperature range: The operating temperature ranges from -45 °C to +125°C. It can handle extreme temperature conditions.
Shock resistance: It can withstand 10 - 2000Hz, 15g vibration, as well as 100g, 6ms mechanical impact.
Protection level: The protection level is up to IP50.
Salt spray corrosion resistance: The salt spray corrosion test duration is > 72h.
Electrical performance
Working current: The cross - sectional area of different contacts corresponds to the working current of 1.5 - 35A.
Operating voltage: DC is 200 - 2.7KV, AC is 150 - 2KV, depending on the distance between contacts.
Test voltage: DC is in the range of 600 - 5KV, AC is in the range of 1.5 - 4.5KV.
Contact resistance: The contact resistance is 2.5 - 10mΩ.
Insulation resistance: Insulation resistance ≥5000M.
Other characteristics
There are various types of needle cores: welded, crimped, PCB straight or curved needle cores, covering fiber, coaxial, thermocouple, gas path, jet and high - pressure signals.
Anti - mixing design: A multi - pin system is used to achieve high contact density and prevent mixing. A variety of positioning pins are optional to avoid misinsertion of similar connectors.
Multi - core high density: The number of cores is 2 - 32. It is a multi - core type and can be installed in high density to save space.
Electromagnetic shielding: It has an all - round shielding effect and is effective in anti - electromagnetic interference.